APPLYING ONTO UNTREATED TIMBER

Product: Ecocel Gold Marine Grade Clear Timber Varnish

Surface Preparation:

Carefully clean and prepare all surfaces, fine sanding and rounding off sharp edges as necessary. Remove all previous paint, varnish, shellac or lacquer and wipe the surface clean of dust.

Applications:

Stir well for 5 minutes and then apply with a soft paintbrush, applicator pad or suitable spray. The first application is a sealer coat. Thinning is not usually necessary but if you prefer, thin with 5% clean water and apply as above. Leave this coat to dry for 1 hour, fill any imperfections, then leave to dry fully for 4 hours before applying further coats.

• Do not apply if temperature is below 10 ºC or if rain is expected within 24 hours.

Coverage

Up to 16 square metres per litre depending on the porosity and application technique.

Gloss Level

Gold Gloss >80% Gold Satin 20-30% (measurement on a 60° gloss meter). These percentages are based on average readings

Drying Time

Leave the sealer coat to dry fully for 4 hours then apply a further 2-3 undiluted coats. Allow 4 hours drying time between each coat. We recommend you give your newly sealed timber a light sanding with 240-grit sandpaper, dusting off thoroughly with a tack rag, before proceeding to apply the undiluted coats.

Clean Up

Wash your equipment in fresh water with a drop of detergent. Rinse in clean water. Seal washings and unwanted leftovers and dispose of responsibly.

Precautions/ First Aid

It is recommended that normal personal protective clothing should be worn, including coveralls, impervious gloves and goggles. Avoid unnecessary skin contact and inhalation. Provide adequate ventilation. If swallowed, contact a doctor or the Poison Information Centre on 13 11 26. Give a glass of water to drink and do not induce vomiting.

 

Disclaimer

The information contained here is given in good faith and is intended to be of assistance to users. The performance of this product is dependant upon its correct preparation, application onto a sound surface and attention to the instructions on the label. The wide variety of surface conditions makes it impossible for the company to assume liability for any loss, consequential or otherwise, arising from the use of this product. Should the product be found defective our liability shall be limited to the replacement of the product only. We reserve the right to amend specifications and application techniques without prior notice.